I[n]solation
Questions & Topics
Windows · Light & Energy Balance
- Why are we trying to turn windows into walls?
- Why does free solar energy have no lobby?
- Why does a building lose more heat than the heating supplies?
- Can new windows also cost us solar heat?
- Which three figures determine a window’s energy balance?
- Why are windows so much thinner than walls?
- Can a window help the heat pump without PV?
FVS · Principles, Construction & Testing
Façade · Sun, Storage & Adaptability
- Why should thermal protection switch between two states?
- Can a façade do more than reduce heat losses?
- When does insulation obstruct the use of solar heat?
- A building’s energy mystery — can you solve it?
- How can solar heat be stored in a solid wall?
- Why Doesn’t a Façade Have a Performance Number?
- How can photovoltaics and dynamic thermal protection work together?
- Why not put photovoltaics on façades as well as roofs?
- What could textured glass do for a façade?
Summer · Shading, Heat & Comfort
Heat Pumps · Peak Loads, PV & Controls
Renovation · Costs, Measurements & Implementation
- What would photovoltaics be without an electricity meter?
- Thermal insulation has a hidden side.
- How can the landlord–tenant dilemma be eased?
- What makes serial renovation successful?
- Why is façade insulation so unpopular?
- Why isn’t there an Amazon for building renovation?
- Can façade insulation and biodiversity go together?
Energy Transition · Ideas, Industry & Society
- Why is the car developing faster than the building site?
- Must we keep expanding renewables without limit?
- Why not generate energy where we need it?
- Is the heating transition’s complexity a problem or an opportunity?
- What could window manufacturers do fundamentally differently?
- Why must the heating transition remain affordable for people?
No matching question found.
A building loses far more heat than its heating system supplies.
And no — the heating system isn't undersized.
It's simpler than that: the heating system isn't the building's only source of heat. The sun supplies heat too, and its share of the energy balance can be considerable.
This creates a difference between the heat a building actually loses and the heat that later has to be replaced by the heating system. The larger the solar gains, the larger that difference can become.
You can see this particularly clearly in a window's energy balance. On the loss side, it's the weakest link in the building envelope — but at the same time it's the main route for solar heat gains.
An older window with Uw ≈ 2.8 W/m²K loses roughly 200 kWh/m² over the heating season in Bielefeld. With the same construction, this loss side stays almost unchanged. But the solar gain side changes substantially with orientation: from around 60 kWh/m² on the north side to 250 kWh/m² on the south side.
So the very same window can look completely different in energy terms — even though its heat losses haven't changed at all.
And this is where the real lever becomes clear: dynamic thermal protection that doesn't obstruct solar gains but acts specifically on the loss side.
An additional thermal resistance of R = 1.25 m²K/W would, in a simplified calculation, reduce an old window's Uw-value from 2.8 W/m²K to around 0.62 W/m²K — a factor of 4.5.
The gain side remains. What changes is the loss side of the balance.
Direct link to this article