A heat pump in an older building doesn't need an ideological debate.

It needs a lower peak load. For heat pumps, “older building” is not a technical exclusion criterion. More important are heating load, heat emitters and the supply temperature needed on cold days. In winter, average temperatures in Germany are generally around freezing or above. Heating load at those temperatures is considerably lower, and many heat pumps can work perfectly sensibly in existing buildings. The critical conditions aren't those normal winter days, but the few cold peaks when the building needs significantly more heat. That's when everything comes together: the building loses more heat, heating load rises, the heating curve is pushed harder and the heat pump operates closer to an unfavourable range. Yet those few hours shape how many existing buildings are assessed. That doesn't necessarily mean the heat pump's output should be questioned. What matters is whether targeted measures can limit the rise in heating load during those critical hours. One major lever is at the window. An older window with Uw ≈ 2.8 W/m²K loses around 84 W/m² at 20 °C indoors and −10 °C outdoors. If a multilayer film composite thermal protection system with U ≈ 0.8 W/m²K is closed in front of it, the simplified calculation gives U ≈ 0.6 W/m²K for the window opening. Heat loss then falls to around 18 W/m². That's about 78% less heat loss at the window. For 20 m² of old window area, that means around 1.3 kW less heating load. With 30 m² of glazing, it's almost 2.0 kW less. And precisely when it matters: on cold nights, at high load and when higher supply temperatures become necessary. Adaptive thermal protection at the window doesn't replace the heat pump. It makes the heat pump's job easier. Open by day for light and solar gains. Closed at night and in cold weather against heat loss. The window becomes a controllable lever for heating load, heating curve and efficiency. Not every existing building needs to become a major construction site first. Sometimes it's enough to deal with the weakest point exactly when the system is under pressure.
Direct link to this article